{"id":989689,"date":"2022-11-16T15:36:19","date_gmt":"2022-11-16T18:36:19","guid":{"rendered":"https:\/\/biogroup.com.ar\/underground-water\/"},"modified":"2026-05-19T15:47:27","modified_gmt":"2026-05-19T18:47:27","slug":"underground-water","status":"publish","type":"page","link":"https:\/\/biogroup.com.ar\/en\/underground-water\/","title":{"rendered":"Underground Water"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"989689\" class=\"elementor elementor-989689\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-20228c98 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"20228c98\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-53e63ad5\" data-id=\"53e63ad5\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-32f1c4f elementor-widget elementor-widget-html\" data-id=\"32f1c4f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"background:linear-gradient(135deg,#030c14 0%,#061828 45%,#030c14 100%);\n  border-radius:12px;padding:48px 36px 36px;border-left:5px solid #e8510a;\n  position:relative;overflow:hidden;\">\n  <div style=\"position:absolute;top:-60px;right:-40px;width:240px;height:240px;\n    border-radius:50%;background:rgba(232,81,10,0.05);pointer-events:none;\"><\/div>\n  <div style=\"position:relative;\">\n    <div style=\"display:inline-flex;align-items:center;gap:8px;background:#e8510a;\n      color:#fff;font-size:11px;font-weight:500;letter-spacing:0.08em;text-transform:uppercase;\n      padding:5px 14px;border-radius:20px;margin-bottom:18px;\">\n      \ud83d\udca7 Monitoring Wells \u00b7 Aquifer Sampling \u00b7 Glyphosate \u00b7 Potability \u00b7 HPLC-MS\/MS \u00b7 Table 2 Decree 831\/93\n    <\/div>\n    <h1 style=\"font-size:36px;font-weight:500;color:#fff;line-height:1.2;\n      margin:0 0 14px;letter-spacing:-0.01em;\">\n      Underground <span style=\"color:#e8510a;\">Water<\/span>\n    <\/h1>\n    <p style=\"font-size:15px;color:rgba(255,255,255,0.85);max-width:680px;\n      line-height:1.6;margin:0 0 10px;font-weight:500;\">\n      Groundwater monitoring well construction, aquifer surveillance, drinking water\n      potability and contaminated site groundwater characterisation.\n    <\/p>\n    <p style=\"font-size:14px;color:rgba(255,255,255,0.7);max-width:680px;\n      line-height:1.65;margin:0 0 14px;\">\n      Biogroup provides a complete groundwater service \u2014 from the <strong style=\"color:#fff;\">\n      design and construction of monitoring wells (phreatimeters)<\/strong> and hydraulic\n      levelling to <strong style=\"color:#fff;\">representative low-flow sampling<\/strong>,\n      full analytical characterisation per <strong style=\"color:#fff;\">Decree 831\/93\n      Table 2<\/strong>, and specialised analysis of pesticides and herbicides by\n      HPLC-MS\/MS \u2014 including glyphosate and AMPA at sub-ppb detection limits.\n    <\/p>\n    <p style=\"font-size:13px;color:rgba(255,255,255,0.55);max-width:680px;\n      line-height:1.65;margin:0 0 28px;\">\n      Whether monitoring a production well for potability compliance, characterising a\n      contaminated plume at a Phase II site investigation, or maintaining a long-term\n      aquifer surveillance network \u2014 Biogroup integrates field work and in-house\n      analytical capability into a single, accountable service.\n    <\/p>\n    <div style=\"border-top:0.5px solid rgba(255,255,255,0.12);padding-top:24px;\n      display:grid;grid-template-columns:repeat(4,1fr);gap:16px;\">\n      <div><div style=\"font-size:20px;font-weight:500;color:#e8510a;line-height:1;\n        margin-bottom:6px;\">Well construction<\/div>\n        <div style=\"font-size:11px;color:rgba(255,255,255,0.5);text-transform:uppercase;\n          letter-spacing:0.06em;line-height:1.3;\">Any geological formation<\/div><\/div>\n      <div><div style=\"font-size:18px;font-weight:500;color:#e8510a;line-height:1;\n        margin-bottom:6px;\">Glyphosate<\/div>\n        <div style=\"font-size:11px;color:rgba(255,255,255,0.5);text-transform:uppercase;\n          letter-spacing:0.06em;line-height:1.3;\">HPLC-MS\/MS \u00b7 sub-ppb<\/div><\/div>\n      <div><div style=\"font-size:18px;font-weight:500;color:#e8510a;line-height:1;\n        margin-bottom:6px;\">Table 2<\/div>\n        <div style=\"font-size:11px;color:rgba(255,255,255,0.5);text-transform:uppercase;\n          letter-spacing:0.06em;line-height:1.3;\">Decree 831\/93 full panel<\/div><\/div>\n      <div><div style=\"font-size:18px;font-weight:500;color:#e8510a;line-height:1;\n        margin-bottom:6px;\">+35 years<\/div>\n        <div style=\"font-size:11px;color:rgba(255,255,255,0.5);text-transform:uppercase;\n          letter-spacing:0.06em;line-height:1.3;\">Groundwater expertise<\/div><\/div>\n    <\/div>\n  <\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-514c7a1a elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"514c7a1a\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-46262cc8\" data-id=\"46262cc8\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-60257ced elementor-widget elementor-widget-html\" data-id=\"60257ced\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"display:grid;grid-template-columns:repeat(3,1fr);gap:12px;\">\n  <div style=\"background:#fff;border:0.5px solid #D3D1C7;border-radius:10px;padding:22px;\">\n    <div style=\"width:42px;height:42px;background:#E6F1FB;border-radius:10px;\n      display:flex;align-items:center;justify-content:center;font-size:22px;margin-bottom:14px;\">\ud83d\udd29<\/div>\n    <div style=\"font-size:14px;font-weight:500;color:#1a1a1a;margin-bottom:6px;\">\n      Field-to-lab integration<\/div>\n    <div style=\"font-size:12.5px;color:#5F5E5A;line-height:1.6;\">Biogroup installs the\n      phreatimeters, collects the samples and analyses them in-house \u2014 eliminating the\n      chain of custody breaks and communication failures that arise when field crews and\n      laboratories are separate organisations. One team, one accountable result.<\/div>\n  <\/div>\n  <div style=\"background:#fff;border:0.5px solid #D3D1C7;border-radius:10px;padding:22px;\">\n    <div style=\"width:42px;height:42px;background:#E1F5EE;border-radius:10px;\n      display:flex;align-items:center;justify-content:center;font-size:22px;margin-bottom:14px;\">\ud83c\udf3f<\/div>\n    <div style=\"font-size:14px;font-weight:500;color:#1a1a1a;margin-bottom:6px;\">\n      Glyphosate and herbicide specialisation<\/div>\n    <div style=\"font-size:12.5px;color:#5F5E5A;line-height:1.6;\">Glyphosate and AMPA\n      in groundwater by HPLC-MS\/MS at sub-ppb detection limits \u2014 critical for the Pampa\n      region where intensive soy agriculture makes these the primary groundwater\n      contamination concern. Full pesticide multi-residue panel available.<\/div>\n  <\/div>\n  <div style=\"background:#fff;border:0.5px solid #D3D1C7;border-radius:10px;padding:22px;\">\n    <div style=\"width:42px;height:42px;background:#FAEEDA;border-radius:10px;\n      display:flex;align-items:center;justify-content:center;font-size:22px;margin-bottom:14px;\">\ud83c\udfdb\ufe0f<\/div>\n    <div style=\"font-size:14px;font-weight:500;color:#1a1a1a;margin-bottom:6px;\">\n      Regulatory comparison<\/div>\n    <div style=\"font-size:12.5px;color:#5F5E5A;line-height:1.6;\">Results reported\n      against Decree 831\/93 Table 2 (groundwater quality guidelines), Argentine Drinking\n      Water Code (CAA Resolution 494\/94, SMR-Q), WHO drinking water guidelines and\n      EPA MCLs \u2014 accepted by SAyDS, OPDS and provincial authorities.<\/div>\n  <\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-29760577 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"29760577\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-668a2b7e\" data-id=\"668a2b7e\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-641e469 elementor-widget elementor-widget-html\" data-id=\"641e469\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"display:flex;align-items:center;gap:10px;margin:8px 0 14px;\">\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n  <span style=\"font-size:12px;font-weight:500;text-transform:uppercase;\n    letter-spacing:0.08em;color:#888780;white-space:nowrap;\">Monitoring well design and construction \u2014 phreatimeters for all geological formations<\/span>\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-61d00bae elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"61d00bae\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-5531aa82\" data-id=\"5531aa82\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-424de1ab elementor-widget elementor-widget-html\" data-id=\"424de1ab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"background:linear-gradient(135deg,#5C3D1F 0%,#7a4e25 100%);\n  border-radius:12px;padding:22px 28px;color:#fff;border-left:5px solid #e8510a;margin-bottom:14px;\">\n  <div style=\"font-size:17px;font-weight:500;color:#fff;margin-bottom:6px;\">\n    A phreatimeter network is only as good as the wells it is built on<\/div>\n  <div style=\"font-size:13px;color:rgba(255,255,255,0.78);line-height:1.65;\">\n    Well design \u2014 screen interval, slot size, casing diameter, gravel pack specification\n    and surface completion \u2014 must be engineered for the specific lithology, aquifer\n    depth and sampling objective. Poorly designed wells produce non-representative\n    samples and unreliable piezometric data.<\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-155a2e29 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"155a2e29\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-149ac5d1\" data-id=\"149ac5d1\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9ec4923 elementor-widget elementor-widget-html\" data-id=\"9ec4923\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"display:grid;grid-template-columns:repeat(3,1fr);gap:10px;margin-bottom:28px;\">\n  <div style=\"border:0.5px solid #D3D1C7;border-radius:10px;background:#fff;overflow:hidden;\"><div style=\"background:#f5f4f0;padding:11px 16px;border-bottom:0.5px solid #D3D1C7;\"><div style=\"font-size:13px;font-weight:500;color:#1a1a1a;\">\ud83d\udd29 Well design<\/div><\/div><div style=\"padding:11px 16px;font-size:12px;color:#2C2C2A;line-height:1.65;\">Engineering of screen interval, slot size (0.2\u20130.5 mm depending on formation grain size), casing material (HDPE or PVC Schedule 40\/80), annular seal design and surface completion \u2014 all matched to lithology, target depth and intended use (contaminant monitoring vs. potability).<\/div><\/div><div style=\"border:0.5px solid #D3D1C7;border-radius:10px;background:#fff;overflow:hidden;\"><div style=\"background:#f5f4f0;padding:11px 16px;border-bottom:0.5px solid #D3D1C7;\"><div style=\"font-size:13px;font-weight:500;color:#1a1a1a;\">\u2699\ufe0f Drilling and installation<\/div><\/div><div style=\"padding:11px 16px;font-size:12px;color:#2C2C2A;line-height:1.65;\">Construction of monitoring wells in any geological formation \u2014 sandy, silty or clay-rich unconsolidated sediments and fractured rock. Hollow-stem auger, mud rotary or direct push depending on formation, depth and presence of volatile contaminants.<\/div><\/div><div style=\"border:0.5px solid #D3D1C7;border-radius:10px;background:#fff;overflow:hidden;\"><div style=\"background:#f5f4f0;padding:11px 16px;border-bottom:0.5px solid #D3D1C7;\"><div style=\"font-size:13px;font-weight:500;color:#1a1a1a;\">\ud83e\udea8 Gravel pack and annular seal<\/div><\/div><div style=\"padding:11px 16px;font-size:12px;color:#2C2C2A;line-height:1.65;\">Placement of filter pack gravel around the screen section and bentonite seal above to prevent vertical leakage between aquifer horizons \u2014 the elements that determine hydraulic isolation and sample representativeness.<\/div><\/div><div style=\"border:0.5px solid #D3D1C7;border-radius:10px;background:#fff;overflow:hidden;\"><div style=\"background:#f5f4f0;padding:11px 16px;border-bottom:0.5px solid #D3D1C7;\"><div style=\"font-size:13px;font-weight:500;color:#1a1a1a;\">\ud83d\udee0\ufe0f Well development<\/div><\/div><div style=\"padding:11px 16px;font-size:12px;color:#2C2C2A;line-height:1.65;\">Air lift, surge and pump development to remove drilling fluid, fines and disturbed material from the gravel pack zone \u2014 until turbidity and field parameters stabilise. Documented with development records.<\/div><\/div><div style=\"border:0.5px solid #D3D1C7;border-radius:10px;background:#fff;overflow:hidden;\"><div style=\"background:#f5f4f0;padding:11px 16px;border-bottom:0.5px solid #D3D1C7;\"><div style=\"font-size:13px;font-weight:500;color:#1a1a1a;\">\ud83e\udea3 Exploratory trenches (calicatas)<\/div><\/div><div style=\"padding:11px 16px;font-size:12px;color:#2C2C2A;line-height:1.65;\">Manual or mechanical excavation of trenches for shallow visual inspection of near-surface stratigraphy, identification of fill materials, buried structures and surface contamination zones inaccessible to drilling.<\/div><\/div><div style=\"border:0.5px solid #D3D1C7;border-radius:10px;background:#fff;overflow:hidden;\"><div style=\"background:#f5f4f0;padding:11px 16px;border-bottom:0.5px solid #D3D1C7;\"><div style=\"font-size:13px;font-weight:500;color:#1a1a1a;\">\ud83d\udccd GPS positioning and optical levelling<\/div><\/div><div style=\"padding:11px 16px;font-size:12px;color:#2C2C2A;line-height:1.65;\">GPS coordinate recording of each well top and ground level. Optical levelling (level instrument and\/or total station) of all well reference elevations relative to a common datum \u2014 the foundation for accurate water table contouring.<\/div><\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f017eb5 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f017eb5\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-91a307d\" data-id=\"91a307d\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-14efcc6a elementor-widget elementor-widget-html\" data-id=\"14efcc6a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"display:flex;align-items:center;gap:10px;margin:8px 0 14px;\">\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n  <span style=\"font-size:12px;font-weight:500;text-transform:uppercase;\n    letter-spacing:0.08em;color:#888780;white-space:nowrap;\">Piezometric level measurement and aquifer monitoring<\/span>\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7b608d09 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7b608d09\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-be78fea\" data-id=\"be78fea\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-37cdff4a elementor-widget elementor-widget-html\" data-id=\"37cdff4a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"border:0.5px solid #D3D1C7;border-radius:12px;background:#fff;overflow:hidden;\">\n  <div style=\"background:linear-gradient(135deg,#0C447C 0%,#1565C0 100%);padding:16px 22px;color:#fff;\">\n    <div style=\"font-size:14px;font-weight:500;color:#fff;margin-bottom:2px;\">\n      Synchronous piezometric measurements \u2014 the data behind the water table map<\/div>\n    <div style=\"font-size:12px;color:rgba(255,255,255,0.85);\">\n      Electronic interface probe \u00b7 0.001 m sensitivity \u00b7 decontaminated between wells \u00b7 GPS-positioned<\/div>\n  <\/div>\n  <div style=\"padding:16px 24px;\">\n    <div style=\"display:grid;grid-template-columns:1fr 1fr;gap:16px;\">\n      <div>\n        <div style=\"font-size:13px;font-weight:500;color:#1a1a1a;margin-bottom:8px;\">\n          Measurement protocol<\/div>\n        <div style=\"font-size:12.5px;color:#2C2C2A;line-height:1.7;\">\n          Depth to water is measured in each well using an <strong>electronic interface\n          probe with 0.001 m sensitivity<\/strong> \u2014 recording depth to water\/product\n          interface (for NAPL detection) and depth to bottom of well. All measurements\n          made synchronously in a single day to ensure water table data reflects\n          true hydraulic conditions at one moment in time. All equipment decontaminated\n          between wells to prevent cross-contamination.<\/div>\n      <\/div>\n      <div>\n        <div style=\"font-size:13px;font-weight:500;color:#1a1a1a;margin-bottom:8px;\">\n          What is produced from level data<\/div>\n        <div style=\"font-size:12px;color:#5F5E5A;line-height:1.75;\">\n          \u2713 Water table elevation at each well (from levelled reference)<br>\n          \u2713 Potentiometric surface contour map (equipotential lines)<br>\n          \u2713 Groundwater flow direction arrows<br>\n          \u2713 Hydraulic gradient calculation<br>\n          \u2713 Free-phase NAPL thickness estimation (if applicable)<br>\n          \u2713 Seasonal variation documentation<br>\n          \u2713 Input data for MODFLOW groundwater flow model\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-2ef567fd elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"2ef567fd\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-50199a05\" data-id=\"50199a05\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-46654f4e elementor-widget elementor-widget-html\" data-id=\"46654f4e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"display:flex;align-items:center;gap:10px;margin:8px 0 14px;\">\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n  <span style=\"font-size:12px;font-weight:500;text-transform:uppercase;\n    letter-spacing:0.08em;color:#888780;white-space:nowrap;\">Groundwater sampling \u2014 representative low-flow protocol<\/span>\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-392e2838 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"392e2838\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-71db1c4b\" data-id=\"71db1c4b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-59ec422b elementor-widget elementor-widget-html\" data-id=\"59ec422b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"border:0.5px solid #D3D1C7;border-radius:12px;background:#fff;overflow:hidden;\">\n  <div style=\"background:#f5f4f0;padding:14px 22px;border-bottom:0.5px solid #D3D1C7;\">\n    <div style=\"font-size:13.5px;font-weight:500;color:#1a1a1a;\">\n      Representative sampling is the most critical quality control step in groundwater monitoring<\/div>\n  <\/div>\n  <div style=\"padding:16px 24px;\">\n    <p style=\"font-size:12.5px;color:#2C2C2A;line-height:1.7;margin:0 0 14px;\">\n      A groundwater sample is only representative of aquifer water if the stagnant water\n      that has been standing in the well casing has been removed before sampling, and if\n      field parameters confirm that formation water \u2014 not casing water \u2014 is being collected.<\/p>\n    <div style=\"display:grid;grid-template-columns:repeat(4,1fr);gap:10px;\">\n      <div style=\"background:#f5f4f0;border-radius:8px;padding:12px 14px;border-left:3px solid #e8510a;\"><div style=\"font-size:12px;font-weight:500;color:#1a1a1a;margin-bottom:4px;\">Well purging<\/div><div style=\"font-size:11.5px;color:#5F5E5A;line-height:1.45;\">Low-flow purging (0.1\u20130.5 L\/min) until pH, conductivity, dissolved oxygen, Eh, turbidity and temperature stabilise \u2014 typically 3\u20135 well volumes. Purge records maintained for QA\/QC.<\/div><\/div><div style=\"background:#f5f4f0;border-radius:8px;padding:12px 14px;border-left:3px solid #e8510a;\"><div style=\"font-size:12px;font-weight:500;color:#1a1a1a;margin-bottom:4px;\">Field parameters<\/div><div style=\"font-size:11.5px;color:#5F5E5A;line-height:1.45;\">Continuous measurement of pH, conductivity (\u00b5S\/cm), dissolved oxygen (mg\/L), oxidation-reduction potential (mV), turbidity (NTU) and temperature (\u00b0C) throughout purging. Stability criteria: <10% variation over 3 consecutive readings.<\/div><\/div><div style=\"background:#f5f4f0;border-radius:8px;padding:12px 14px;border-left:3px solid #e8510a;\"><div style=\"font-size:12px;font-weight:500;color:#1a1a1a;margin-bottom:4px;\">Sample collection<\/div><div style=\"font-size:11.5px;color:#5F5E5A;line-height:1.45;\">Samples collected through dedicated low-flow pump or bailer after stabilisation. Transferred directly to laboratory-prepared containers \u2014 pre-acidified for metals, preserved with HCl\/Na\u2082S\u2082O\u2083 for VOCs. No headspace in VOC containers.<\/div><\/div><div style=\"background:#f5f4f0;border-radius:8px;padding:12px 14px;border-left:3px solid #e8510a;\"><div style=\"font-size:12px;font-weight:500;color:#1a1a1a;margin-bottom:4px;\">Chain of custody<\/div><div style=\"font-size:11.5px;color:#5F5E5A;line-height:1.45;\">Temperature-controlled sample transport (4\u00b0C), documented chain of custody from well to laboratory, preservation verification on arrival, laboratory receipt confirmation.<\/div><\/div>\n    <\/div>\n  <\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-b6633d7 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"b6633d7\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6d1bc59e\" data-id=\"6d1bc59e\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-11b81d38 elementor-widget elementor-widget-html\" data-id=\"11b81d38\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"display:flex;align-items:center;gap:10px;margin:8px 0 14px;\">\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n  <span style=\"font-size:12px;font-weight:500;text-transform:uppercase;\n    letter-spacing:0.08em;color:#888780;white-space:nowrap;\">Drinking water analysis \u2014 potability assessment<\/span>\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-251c86d4 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"251c86d4\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2a12d781\" data-id=\"2a12d781\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-676bbba3 elementor-widget elementor-widget-html\" data-id=\"676bbba3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"border:0.5px solid #D3D1C7;border-radius:12px;background:#fff;overflow:hidden;\">\n  <div style=\"background:linear-gradient(135deg,#085041 0%,#0F6E56 100%);padding:16px 22px;color:#fff;\">\n    <div style=\"font-size:14px;font-weight:500;color:#fff;margin-bottom:2px;\">\n      Complete potability panels for supply wells, production wells and water supply systems<\/div>\n    <div style=\"font-size:12px;color:rgba(255,255,255,0.85);\">\n      Argentine CAA Resolution 494\/94 (SMR-Q) \u00b7 WHO Guidelines (2022) \u00b7 EPA MCLs<\/div>\n  <\/div>\n  <div style=\"padding:16px 24px;\">\n    <div style=\"display:grid;grid-template-columns:repeat(3,1fr);gap:12px;\">\n\n      <div style=\"border:0.5px solid #D3D1C7;border-radius:8px;overflow:hidden;\">\n        <div style=\"background:#D6F0EA;padding:10px 14px;border-bottom:0.5px solid #D3D1C7;\">\n          <div style=\"font-size:12.5px;font-weight:500;color:#085041;\">\u2697\ufe0f Physicochemical<\/div>\n        <\/div>\n        <div style=\"padding:10px 14px;\">\n          <div style=\"font-size:12px;color:#2C2C2A;line-height:1.7;\">\n            pH \u00b7 conductivity \u00b7 turbidity \u00b7 colour \u00b7 odour \u00b7 taste \u00b7\n            total dissolved solids (TDS) \u00b7 hardness (total, Ca, Mg) \u00b7\n            alkalinity \u00b7 acidity \u00b7 dissolved oxygen \u00b7 redox potential \u00b7\n            iron (total, dissolved) \u00b7 manganese \u00b7 silica\n          <\/div>\n        <\/div>\n      <\/div>\n\n      <div style=\"border:0.5px solid #D3D1C7;border-radius:8px;overflow:hidden;\">\n        <div style=\"background:#E6F1FB;padding:10px 14px;border-bottom:0.5px solid #D3D1C7;\">\n          <div style=\"font-size:12.5px;font-weight:500;color:#0C447C;\">\ud83d\udc8a Macro-ions and nutrients<\/div>\n        <\/div>\n        <div style=\"padding:10px 14px;\">\n          <div style=\"font-size:12px;color:#2C2C2A;line-height:1.7;\">\n            Chlorides \u00b7 sulphates \u00b7 nitrates (NO\u2083\u207b) \u00b7 nitrites (NO\u2082\u207b) \u00b7\n            ammonium (NH\u2084\u207a) \u00b7 phosphates \u00b7 fluorides \u00b7 bromides \u00b7\n            sodium \u00b7 potassium \u00b7 calcium \u00b7 magnesium \u00b7\n            bicarbonates \u00b7 carbonates \u00b7 SAR index\n          <\/div>\n        <\/div>\n      <\/div>\n\n      <div style=\"border:0.5px solid #D3D1C7;border-radius:8px;overflow:hidden;\">\n        <div style=\"background:#FCEBEB;padding:10px 14px;border-bottom:0.5px solid #D3D1C7;\">\n          <div style=\"font-size:12.5px;font-weight:500;color:#791F1F;\">\u2620\ufe0f Trace metals and metalloids<\/div>\n        <\/div>\n        <div style=\"padding:10px 14px;\">\n          <div style=\"font-size:12px;color:#2C2C2A;line-height:1.7;\">\n            Arsenic (As) \u00b7 Antimony (Sb) \u00b7 Barium (Ba) \u00b7 Cadmium (Cd) \u00b7\n            Chromium total \u00b7 Cr(VI) \u00b7 Lead (Pb) \u00b7 Mercury (Hg) \u00b7 Nickel (Ni) \u00b7\n            Selenium (Se) \u00b7 Zinc (Zn) \u00b7 Copper (Cu) \u00b7 Iron \u00b7 Manganese \u00b7\n            by ICP-MS at \u00b5g\/L (ppb) levels\n          <\/div>\n        <\/div>\n      <\/div>\n\n    <\/div>\n  <\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-31b27910 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"31b27910\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-469083b9\" data-id=\"469083b9\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-241f96c elementor-widget elementor-widget-html\" data-id=\"241f96c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"display:flex;align-items:center;gap:10px;margin:8px 0 14px;\">\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n  <span style=\"font-size:12px;font-weight:500;text-transform:uppercase;\n    letter-spacing:0.08em;color:#888780;white-space:nowrap;\">Glyphosate and AMPA \u2014 the priority herbicide in Argentine groundwater<\/span>\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-78f71f07 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"78f71f07\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-574ce49b\" data-id=\"574ce49b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3e4c4a39 elementor-widget elementor-widget-html\" data-id=\"3e4c4a39\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"border:0.5px solid #D3D1C7;border-radius:12px;background:#fff;overflow:hidden;\">\n  <div style=\"background:linear-gradient(135deg,#085041 0%,#0F6E56 100%);padding:16px 22px;color:#fff;\">\n    <div style=\"font-size:14px;font-weight:500;color:#fff;margin-bottom:2px;\">\n      Glyphosate and AMPA analysis by HPLC-MS\/MS \u2014 the analytical challenge solved<\/div>\n    <div style=\"font-size:12px;color:rgba(255,255,255,0.85);\">\n      Sub-ppb detection limits \u00b7 HPLC-MS\/MS \u00b7 derivatisation protocol \u00b7 water matrix \u00b7\n      Argentine and WHO guideline comparison<\/div>\n  <\/div>\n  <div style=\"padding:18px 26px;\">\n    <div style=\"display:grid;grid-template-columns:1fr 1fr;gap:20px;\">\n      <div>\n        <div style=\"font-size:13px;font-weight:500;color:#1a1a1a;margin-bottom:8px;\">\n          Why glyphosate is the critical herbicide in Argentine groundwater<\/div>\n        <div style=\"font-size:12.5px;color:#2C2C2A;line-height:1.7;\">\n          Argentina is the world's third-largest user of glyphosate \u2014 applied intensively\n          across soybean, maize and sunflower crops in the Pampa region. Glyphosate is\n          polar, water-soluble and resistant to hydrolysis, giving it significant mobility\n          in the soil-water system. AMPA (aminomethylphosphonic acid) is the primary\n          degradation product and is equally regulated.<br><br>\n          Despite its widespread use, glyphosate analysis in water is technically demanding \u2014\n          its highly polar, ionic character makes it poorly retained on standard reversed-phase\n          HPLC columns, and it requires either derivatisation (FMOC-Cl) or HILIC\/ion-pair\n          chromatography for reliable quantification.<\/div>\n      <\/div>\n      <div>\n        <div style=\"font-size:13px;font-weight:500;color:#1a1a1a;margin-bottom:8px;\">\n          Biogroup's analytical approach<\/div>\n        <div style=\"font-size:12px;color:#5F5E5A;line-height:1.75;\">\n          \u2713 <strong>Method:<\/strong> HPLC-MS\/MS with FMOC-Cl derivatisation or direct\n          LC-MS\/MS (HILIC column)<br>\n          \u2713 <strong>Detection limit:<\/strong> 0.05 \u00b5g\/L (0.05 ppb) \u2014 below all\n          applicable regulatory thresholds<br>\n          \u2713 <strong>Analytes:<\/strong> Glyphosate + AMPA (metabolite) reported individually<br>\n          \u2713 <strong>Argentine guideline:<\/strong> 0.9 mg\/L (CAA Resolution 494\/94) \u2014 note\n          that this limit predates modern risk assessments<br>\n          \u2713 <strong>WHO guideline:<\/strong> 1 mg\/L<br>\n          \u2713 <strong>EU limit (drinking water):<\/strong> 0.1 \u00b5g\/L (individual pesticide)<br>\n          \u2713 <strong>Full pesticide multi-residue panel<\/strong> also available (100+ compounds)\n        <\/div>\n        <div style=\"background:#E1F5EE;border-left:3px solid #085041;border-radius:6px;\n          padding:10px 12px;margin-top:10px;\">\n          <div style=\"font-size:12px;color:#2C2C2A;line-height:1.55;\">\n            Biogroup also analyses the full organophosphate and organochlorine pesticide\n            panels in groundwater \u2014 atrazine, acetochlor, endosulfan, chlorpyrifos and\n            80+ additional compounds by GC-MS and HPLC-MS\/MS.\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-8f21d06 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"8f21d06\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-66d8a4aa\" data-id=\"66d8a4aa\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-14f0bc39 elementor-widget elementor-widget-html\" data-id=\"14f0bc39\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"display:flex;align-items:center;gap:10px;margin:8px 0 14px;\">\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n  <span style=\"font-size:12px;font-weight:500;text-transform:uppercase;\n    letter-spacing:0.08em;color:#888780;white-space:nowrap;\">Contaminated site groundwater analysis \u2014 Table 2 Decree 831\/93 full panel<\/span>\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7f3a325d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7f3a325d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-5f2a13bd\" data-id=\"5f2a13bd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-11e91eba elementor-widget elementor-widget-html\" data-id=\"11e91eba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"border:0.5px solid #D3D1C7;border-radius:12px;background:#fff;overflow:hidden;\">\n  <div style=\"background:linear-gradient(135deg,#0C447C 0%,#1565C0 100%);padding:16px 22px;color:#fff;\">\n    <div style=\"font-size:14px;font-weight:500;color:#fff;margin-bottom:2px;\">\n      Complete Decree 831\/93 Table 2 analytical capability \u2014 groundwater quality guidelines<\/div>\n    <div style=\"font-size:12px;color:rgba(255,255,255,0.85);\">\n      Full contaminant panel \u00b7 EPA SW-846 methods \u00b7 GC-MS \u00b7 ICP-MS \u00b7 HPLC-MS\/MS \u00b7\n      results reported vs. Table 2 thresholds<\/div>\n  <\/div>\n  <div style=\"padding:16px 24px;\">\n    <p style=\"font-size:12.5px;color:#2C2C2A;line-height:1.65;margin:0 0 14px;\">\n      For contaminated site investigations (Phase II ESA), remediation monitoring and\n      regulatory submissions, Biogroup provides the complete groundwater contaminant\n      panel with results compared against Decree 831\/93 Table 2 groundwater quality\n      guidelines \u2014 the Argentine regulatory reference for contaminated site decisions.<\/p>\n    <div style=\"display:grid;grid-template-columns:repeat(4,1fr);gap:8px;\">\n      <div style=\"background:#f5f4f0;border-radius:6px;padding:9px 12px;border-left:2px solid #e8510a;\"><div style=\"font-size:12px;font-weight:500;color:#1a1a1a;margin-bottom:3px;\">TPH fractions<\/div><div style=\"font-size:11px;color:#5F5E5A;line-height:1.35;\">GRO \u00b7 DRO \u00b7 MRO \u00b7 TX-1005\/1006 \u00b7 GC-FID<\/div><\/div><div style=\"background:#f5f4f0;border-radius:6px;padding:9px 12px;border-left:2px solid #e8510a;\"><div style=\"font-size:12px;font-weight:500;color:#1a1a1a;margin-bottom:3px;\">BTEX<\/div><div style=\"font-size:11px;color:#5F5E5A;line-height:1.35;\">Benzene \u00b7 toluene \u00b7 ethylbenzene \u00b7 xylenes \u00b7 GC-MS purge-and-trap<\/div><\/div><div style=\"background:#f5f4f0;border-radius:6px;padding:9px 12px;border-left:2px solid #e8510a;\"><div style=\"font-size:12px;font-weight:500;color:#1a1a1a;margin-bottom:3px;\">MTBE \/ TAME<\/div><div style=\"font-size:11px;color:#5F5E5A;line-height:1.35;\">Fuel oxygenates \u00b7 GC-MS headspace \u00b7 Table 2<\/div><\/div><div style=\"background:#f5f4f0;border-radius:6px;padding:9px 12px;border-left:2px solid #e8510a;\"><div style=\"font-size:12px;font-weight:500;color:#1a1a1a;margin-bottom:3px;\">VOCs & SVOCs<\/div><div style=\"font-size:11px;color:#5F5E5A;line-height:1.35;\">EPA 8260B \u00b7 EPA 8270D \u00b7 60+ compounds<\/div><\/div><div style=\"background:#f5f4f0;border-radius:6px;padding:9px 12px;border-left:2px solid #e8510a;\"><div style=\"font-size:12px;font-weight:500;color:#1a1a1a;margin-bottom:3px;\">PAHs<\/div><div style=\"font-size:11px;color:#5F5E5A;line-height:1.35;\">16 EPA priority \u00b7 HPLC-FLD \u00b7 benzo(a)pyrene<\/div><\/div><div style=\"background:#f5f4f0;border-radius:6px;padding:9px 12px;border-left:2px solid #e8510a;\"><div style=\"font-size:12px;font-weight:500;color:#1a1a1a;margin-bottom:3px;\">Chlorinated solvents<\/div><div style=\"font-size:11px;color:#5F5E5A;line-height:1.35;\">TCE \u00b7 PCE \u00b7 DCE \u00b7 VC \u00b7 GC-MS \u00b7 EPA 8260<\/div><\/div><div style=\"background:#f5f4f0;border-radius:6px;padding:9px 12px;border-left:2px solid #e8510a;\"><div style=\"font-size:12px;font-weight:500;color:#1a1a1a;margin-bottom:3px;\">Heavy metals<\/div><div style=\"font-size:11px;color:#5F5E5A;line-height:1.35;\">ICP-MS \u00b7 As\/Cd\/Cr\/Pb\/Hg\/Ni\/Zn \u00b7 EPA 3005A<\/div><\/div><div style=\"background:#f5f4f0;border-radius:6px;padding:9px 12px;border-left:2px solid #e8510a;\"><div style=\"font-size:12px;font-weight:500;color:#1a1a1a;margin-bottom:3px;\">Cr(VI)<\/div><div style=\"font-size:11px;color:#5F5E5A;line-height:1.35;\">Hexavalent chromium \u00b7 colorimetric\/IC \u00b7 EPA 3060A<\/div><\/div><div style=\"background:#f5f4f0;border-radius:6px;padding:9px 12px;border-left:2px solid #e8510a;\"><div style=\"font-size:12px;font-weight:500;color:#1a1a1a;margin-bottom:3px;\">Pesticides<\/div><div style=\"font-size:11px;color:#5F5E5A;line-height:1.35;\">OC \u00b7 OP \u00b7 glyphosate \u00b7 HPLC-MS\/MS \u00b7 GC-MS<\/div><\/div><div style=\"background:#f5f4f0;border-radius:6px;padding:9px 12px;border-left:2px solid #e8510a;\"><div style=\"font-size:12px;font-weight:500;color:#1a1a1a;margin-bottom:3px;\">PCBs<\/div><div style=\"font-size:11px;color:#5F5E5A;line-height:1.35;\">GC-ECD \u00b7 EPA 8082A \u00b7 Aroclor series<\/div><\/div><div style=\"background:#f5f4f0;border-radius:6px;padding:9px 12px;border-left:2px solid #e8510a;\"><div style=\"font-size:12px;font-weight:500;color:#1a1a1a;margin-bottom:3px;\">Cyanides<\/div><div style=\"font-size:11px;color:#5F5E5A;line-height:1.35;\">Free + total \u00b7 colorimetric \u00b7 IC<\/div><\/div><div style=\"background:#f5f4f0;border-radius:6px;padding:9px 12px;border-left:2px solid #e8510a;\"><div style=\"font-size:12px;font-weight:500;color:#1a1a1a;margin-bottom:3px;\">Inorganic anions<\/div><div style=\"font-size:11px;color:#5F5E5A;line-height:1.35;\">Nitrates \u00b7 sulphates \u00b7 chlorides \u00b7 fluorides \u00b7 IC<\/div><\/div>\n    <\/div>\n  <\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-31d4c229 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"31d4c229\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-38a794a0\" data-id=\"38a794a0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7b27cde1 elementor-widget elementor-widget-html\" data-id=\"7b27cde1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"display:flex;align-items:center;gap:10px;margin:8px 0 14px;\">\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n  <span style=\"font-size:12px;font-weight:500;text-transform:uppercase;\n    letter-spacing:0.08em;color:#888780;white-space:nowrap;\">Long-term aquifer monitoring network management<\/span>\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-38feb6a7 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"38feb6a7\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-20e64ae0\" data-id=\"20e64ae0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-290c2171 elementor-widget elementor-widget-html\" data-id=\"290c2171\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"display:grid;grid-template-columns:1fr 1fr;gap:12px;margin-bottom:28px;\">\n  <div style=\"border:0.5px solid #D3D1C7;border-radius:10px;background:#fff;overflow:hidden;\">\n    <div style=\"background:#E6F1FB;padding:12px 18px;border-bottom:0.5px solid #D3D1C7;\">\n      <div style=\"font-size:13.5px;font-weight:500;color:#1a1a1a;\">\ud83d\udcca Periodic monitoring campaigns<\/div>\n    <\/div>\n    <div style=\"padding:14px 18px;\">\n      <div style=\"font-size:12.5px;color:#2C2C2A;line-height:1.65;margin-bottom:8px;\">\n        Scheduled monitoring campaigns (monthly, quarterly, semi-annual or annual) with\n        synchronous level measurement and groundwater sampling across all network wells.\n        Required for: contaminated site remediation monitoring, landfill environmental\n        surveillance, industrial facility groundwater compliance and regulatory reporting.<\/div>\n      <div style=\"font-size:12px;color:#5F5E5A;line-height:1.7;\">\n        \u2713 Full level-and-sample campaign per monitoring round<br>\n        \u2713 Trend analysis \u2014 contaminant concentration vs. time<br>\n        \u2713 Water table contouring each round<br>\n        \u2713 Comparison against previous rounds<br>\n        \u2713 Exceedance flag and regulatory reporting\n      <\/div>\n    <\/div>\n  <\/div>\n  <div style=\"border:0.5px solid #D3D1C7;border-radius:10px;background:#fff;overflow:hidden;\">\n    <div style=\"background:#E1F5EE;padding:12px 18px;border-bottom:0.5px solid #D3D1C7;\">\n      <div style=\"font-size:13.5px;font-weight:500;color:#1a1a1a;\">\ud83d\udccb Monitoring reports<\/div>\n    <\/div>\n    <div style=\"padding:14px 18px;\">\n      <div style=\"font-size:12.5px;color:#2C2C2A;line-height:1.65;margin-bottom:8px;\">\n        Each monitoring campaign produces a complete report submitted to the\n        site owner and, where required, to regulatory authorities \u2014 documenting\n        levels, analytical results, trend analysis, exceedances and recommendations.<\/div>\n      <div style=\"font-size:12px;color:#5F5E5A;line-height:1.7;\">\n        \u2713 Piezometric level table and water table map<br>\n        \u2713 Full analytical results with laboratory certificates<br>\n        \u2713 Comparison against Table 2 \/ Table 9 screening levels<br>\n        \u2713 Concentration trend plots for each analyte and well<br>\n        \u2713 Plume extent assessment<br>\n        \u2713 Remediation system performance evaluation (if applicable)\n      <\/div>\n    <\/div>\n  <\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5bd9cbff elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5bd9cbff\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-9215b16\" data-id=\"9215b16\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-48cba7d9 elementor-widget elementor-widget-html\" data-id=\"48cba7d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"display:flex;align-items:center;gap:10px;margin:8px 0 14px;\">\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n  <span style=\"font-size:12px;font-weight:500;text-transform:uppercase;\n    letter-spacing:0.08em;color:#888780;white-space:nowrap;\">Applications \u2014 when underground water monitoring is required<\/span>\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-e8265d6 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e8265d6\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-33c5535b\" data-id=\"33c5535b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-693e7f10 elementor-widget elementor-widget-html\" data-id=\"693e7f10\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"display:grid;grid-template-columns:repeat(3,1fr);gap:10px;margin-bottom:28px;\">\n  <div style=\"background:#fff;border:0.5px solid #D3D1C7;border-radius:10px;padding:18px 16px;\"><div style=\"font-size:22px;margin-bottom:8px;\">\u26fd<\/div><div style=\"font-size:13.5px;font-weight:500;color:#1a1a1a;margin-bottom:6px;\">Petrol stations &amp; fuel spills<\/div><div style=\"font-size:12px;color:#5F5E5A;line-height:1.6;\">BTEX, MTBE and TPH in shallow aquifer. Plume monitoring during active remediation. Required for Phase II characterisation and closure certification.<\/div><\/div><div style=\"background:#fff;border:0.5px solid #D3D1C7;border-radius:10px;padding:18px 16px;\"><div style=\"font-size:22px;margin-bottom:8px;\">\ud83c\udf3e<\/div><div style=\"font-size:13.5px;font-weight:500;color:#1a1a1a;margin-bottom:6px;\">Agricultural zones<\/div><div style=\"font-size:12px;color:#5F5E5A;line-height:1.6;\">Nitrates, glyphosate, AMPA and pesticide residues in phreatic aquifer. Drinking water quality of private production wells.<\/div><\/div><div style=\"background:#fff;border:0.5px solid #D3D1C7;border-radius:10px;padding:18px 16px;\"><div style=\"font-size:22px;margin-bottom:8px;\">\ud83d\uddd1\ufe0f<\/div><div style=\"font-size:13.5px;font-weight:500;color:#1a1a1a;margin-bottom:6px;\">Landfills<\/div><div style=\"font-size:12px;color:#5F5E5A;line-height:1.6;\">Leachate plume impact assessment on downgradient groundwater. Regulatory monitoring network per Ley 24.051 and provincial waste facility requirements.<\/div><\/div><div style=\"background:#fff;border:0.5px solid #D3D1C7;border-radius:10px;padding:18px 16px;\"><div style=\"font-size:22px;margin-bottom:8px;\">\ud83c\udfed<\/div><div style=\"font-size:13.5px;font-weight:500;color:#1a1a1a;margin-bottom:6px;\">Industrial facilities<\/div><div style=\"font-size:12px;color:#5F5E5A;line-height:1.6;\">Baseline groundwater quality and ongoing compliance monitoring. Phase II investigation support \u2014 sampling, analysis and plume characterisation.<\/div><\/div><div style=\"background:#fff;border:0.5px solid #D3D1C7;border-radius:10px;padding:18px 16px;\"><div style=\"font-size:22px;margin-bottom:8px;\">\ud83c\udfe1<\/div><div style=\"font-size:13.5px;font-weight:500;color:#1a1a1a;margin-bottom:6px;\">Potability of supply wells<\/div><div style=\"font-size:12px;color:#5F5E5A;line-height:1.6;\">Physicochemical and microbiological potability panels for private and municipal supply wells, swimming pools and industrial process water.<\/div><\/div><div style=\"background:#fff;border:0.5px solid #D3D1C7;border-radius:10px;padding:18px 16px;\"><div style=\"font-size:22px;margin-bottom:8px;\">\ud83c\udfd7\ufe0f<\/div><div style=\"font-size:13.5px;font-weight:500;color:#1a1a1a;margin-bottom:6px;\">Construction &amp; development<\/div><div style=\"font-size:12px;color:#5F5E5A;line-height:1.6;\">Pre-construction groundwater baseline. Dewatering water quality monitoring. Assessment of groundwater impact from construction activities.<\/div><\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-d9c99ec elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"d9c99ec\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6a5cabe9\" data-id=\"6a5cabe9\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-78d56c0f elementor-widget elementor-widget-html\" data-id=\"78d56c0f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"display:flex;align-items:center;gap:10px;margin:8px 0 14px;\">\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n  <span style=\"font-size:12px;font-weight:500;text-transform:uppercase;\n    letter-spacing:0.08em;color:#888780;white-space:nowrap;\">Regulatory framework \u2014 groundwater quality standards<\/span>\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-167b6a43 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"167b6a43\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1d14df63\" data-id=\"1d14df63\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-46aeef72 elementor-widget elementor-widget-html\" data-id=\"46aeef72\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"display:grid;grid-template-columns:repeat(3,1fr);gap:12px;margin-bottom:28px;\">\n  <div style=\"border:0.5px solid #D3D1C7;border-radius:10px;background:#fff;overflow:hidden;\">\n    <div style=\"background:#f5f4f0;padding:12px 16px;border-bottom:0.5px solid #D3D1C7;\">\n      <div style=\"font-size:13px;font-weight:500;color:#1a1a1a;\">\ud83c\udde6\ud83c\uddf7 Argentine standards<\/div>\n    <\/div>\n    <div style=\"padding:12px 16px;\">\n      <div style=\"font-size:12px;color:#2C2C2A;line-height:1.75;\">\n        \u2022 <strong>Decree 831\/93 Table 2<\/strong> \u2014 groundwater quality guidelines<br>\n        \u2022 <strong>Decree 831\/93 Table 9<\/strong> \u2014 soil guideline values (cross-ref)<br>\n        \u2022 <strong>CAA Res. 494\/94<\/strong> (SMR-Q) \u2014 drinking water standard<br>\n        \u2022 <strong>Ley 24.051<\/strong> \u2014 hazardous waste \/ groundwater protection<br>\n        \u2022 <strong>ENOHSA \/ ERAS<\/strong> \u2014 drinking water regulatory framework<br>\n        \u2022 <strong>Provincial<\/strong> \u2014 Santa Fe \u00b7 Buenos Aires \u00b7 C\u00f3rdoba regulations\n      <\/div>\n    <\/div>\n  <\/div>\n  <div style=\"border:0.5px solid #D3D1C7;border-radius:10px;background:#fff;overflow:hidden;\">\n    <div style=\"background:#f5f4f0;padding:12px 16px;border-bottom:0.5px solid #D3D1C7;\">\n      <div style=\"font-size:13px;font-weight:500;color:#1a1a1a;\">\ud83c\udf0d WHO Guidelines<\/div>\n    <\/div>\n    <div style=\"padding:12px 16px;\">\n      <div style=\"font-size:12px;color:#2C2C2A;line-height:1.75;\">\n        \u2022 <strong>WHO Guidelines for Drinking Water Quality<\/strong> (4th ed. 2022)<br>\n        \u2022 Arsenic: 10 \u00b5g\/L \u00b7 Nitrates: 50 mg\/L<br>\n        \u2022 Glyphosate: 1 mg\/L (provisional)<br>\n        \u2022 Fluoride: 1.5 mg\/L<br>\n        \u2022 Cryptosporidium \/ Giardia: treatment targets<br>\n        \u2022 E. coli: absent in 100 mL\n      <\/div>\n    <\/div>\n  <\/div>\n  <div style=\"border:0.5px solid #D3D1C7;border-radius:10px;background:#fff;overflow:hidden;\">\n    <div style=\"background:#f5f4f0;padding:12px 16px;border-bottom:0.5px solid #D3D1C7;\">\n      <div style=\"font-size:13px;font-weight:500;color:#1a1a1a;\">\ud83c\uddfa\ud83c\uddf8 EPA standards<\/div>\n    <\/div>\n    <div style=\"padding:12px 16px;\">\n      <div style=\"font-size:12px;color:#2C2C2A;line-height:1.75;\">\n        \u2022 <strong>EPA MCLs<\/strong> \u2014 Maximum Contaminant Levels (40 CFR Part 141)<br>\n        \u2022 <strong>EPA RSLs<\/strong> \u2014 Regional Screening Levels (groundwater)<br>\n        \u2022 Arsenic: 10 \u00b5g\/L \u00b7 Lead: 15 \u00b5g\/L (action level)<br>\n        \u2022 Benzene: 5 \u00b5g\/L \u00b7 TCE: 5 \u00b5g\/L<br>\n        \u2022 MTBE: 20 \u00b5g\/L (secondary, taste\/odour)<br>\n        \u2022 <strong>SW-846<\/strong> \u2014 analytical methods for groundwater\n      <\/div>\n    <\/div>\n  <\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-42c2c439 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"42c2c439\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-239dca69\" data-id=\"239dca69\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-911600c elementor-widget elementor-widget-html\" data-id=\"911600c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"display:flex;align-items:center;gap:10px;margin:8px 0 14px;\">\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n  <span style=\"font-size:12px;font-weight:500;text-transform:uppercase;\n    letter-spacing:0.08em;color:#888780;white-space:nowrap;\">Related services<\/span>\n  <div style=\"flex:1;height:0.5px;background:#D3D1C7;\"><\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-38c2ba85 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"38c2ba85\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-75e29fd8\" data-id=\"75e29fd8\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-689fe414 elementor-widget elementor-widget-html\" data-id=\"689fe414\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"display:grid;grid-template-columns:repeat(4,1fr);gap:10px;margin-bottom:28px;\">\n  <a href=\"https:\/\/biogroup.com.ar\/en\/geology-and-hydrogeology\/\" style=\"background:#f5f4f0;border:0.5px solid #D3D1C7;border-radius:8px;padding:14px 14px;text-decoration:none;display:block;\"><div style=\"font-size:12.5px;font-weight:500;color:#1a1a1a;margin-bottom:3px;\">\ud83c\udf0d Geology &amp; Hydrogeology \u2192<\/div><div style=\"font-size:11px;color:#5F5E5A;line-height:1.3;\">Phreatimeters \u00b7 MODFLOW \u00b7 RT3D \u00b7 VES<\/div><\/a><a href=\"https:\/\/biogroup.com.ar\/en\/remediation-of-contaminated-sites\/\" style=\"background:#f5f4f0;border:0.5px solid #D3D1C7;border-radius:8px;padding:14px 14px;text-decoration:none;display:block;\"><div style=\"font-size:12.5px;font-weight:500;color:#1a1a1a;margin-bottom:3px;\">\ud83c\udf31 Sites Remediation \u2192<\/div><div style=\"font-size:11px;color:#5F5E5A;line-height:1.3;\">ISCO \u00b7 bioremediation \u00b7 MNA \u00b7 pump-and-treat<\/div><\/a><a href=\"https:\/\/biogroup.com.ar\/en\/soil-monitoring\/\" style=\"background:#f5f4f0;border:0.5px solid #D3D1C7;border-radius:8px;padding:14px 14px;text-decoration:none;display:block;\"><div style=\"font-size:12.5px;font-weight:500;color:#1a1a1a;margin-bottom:3px;\">\ud83c\udfde\ufe0f Soil Monitoring \u2192<\/div><div style=\"font-size:11px;color:#5F5E5A;line-height:1.3;\">TPH \u00b7 BTEX \u00b7 metals \u00b7 PAHs \u00b7 Table 9<\/div><\/a><a href=\"https:\/\/biogroup.com.ar\/en\/water-wastewater\/\" style=\"background:#f5f4f0;border:0.5px solid #D3D1C7;border-radius:8px;padding:14px 14px;text-decoration:none;display:block;\"><div style=\"font-size:12.5px;font-weight:500;color:#1a1a1a;margin-bottom:3px;\">\ud83d\udca7 Water &amp; Wastewater \u2192<\/div><div style=\"font-size:11px;color:#5F5E5A;line-height:1.3;\">Industrial effluent \u00b7 DBO \u00b7 heavy metals<\/div><\/a>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-181d43bf elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"181d43bf\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-47b2a5b\" data-id=\"47b2a5b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3887733f elementor-widget elementor-widget-html\" data-id=\"3887733f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div style=\"background:linear-gradient(135deg,#030c14 0%,#061828 100%);\n  border-radius:12px;padding:36px 38px;text-align:center;\n  border-left:5px solid #e8510a;position:relative;overflow:hidden;\">\n  <div style=\"position:absolute;top:-30px;right:-30px;width:140px;height:140px;\n    border-radius:50%;background:rgba(232,81,10,0.08);\"><\/div>\n  <div style=\"position:relative;\">\n    <div style=\"display:inline-block;background:rgba(232,81,10,0.15);color:#e8510a;\n      font-size:11px;font-weight:500;padding:5px 14px;border-radius:20px;\n      letter-spacing:0.08em;text-transform:uppercase;margin-bottom:14px;\">\n      Monitoring Wells \u00b7 Aquifer Sampling \u00b7 Glyphosate \u00b7 Potability \u00b7 Table 2\n    <\/div>\n    <div style=\"font-size:24px;font-weight:500;color:#fff;margin-bottom:8px;line-height:1.3;\">\n      Need groundwater monitoring or analysis?<\/div>\n    <div style=\"font-size:14px;color:rgba(255,255,255,0.7);margin-bottom:24px;\n      max-width:600px;margin-left:auto;margin-right:auto;line-height:1.65;\">\n      From potability testing of a supply well to a full contaminated site monitoring\n      network \u2014 Biogroup provides well construction, representative sampling and\n      complete analytical characterisation in one integrated service.\n    <\/div>\n    <a href=\"https:\/\/biogroup.com.ar\/en\/contact\/\" style=\"display:inline-block;\n      background:#e8510a;color:#fff;font-size:14.5px;font-weight:500;\n      text-decoration:none;padding:14px 36px;border-radius:8px;letter-spacing:0.02em;\">\n      Request a groundwater study \u2192<\/a>\n    <div style=\"margin-top:24px;padding-top:20px;border-top:0.5px solid rgba(255,255,255,0.12);\n      display:flex;gap:24px;justify-content:center;flex-wrap:wrap;\n      font-size:12px;color:rgba(255,255,255,0.55);\">\n      <span>\ud83d\udcde +54 341 425-6431<\/span>\n      <span>\ud83d\udcde +54 341 447-4486<\/span>\n      <span>\u2709 biogroup@biogroup.com.ar<\/span>\n      <span>\ud83d\udccd 3 de febrero 920 \u00b7 Rosario, Argentina<\/span>\n      <span>Mon\u2013Fri 08:00\u201317:00<\/span>\n    <\/div>\n  <\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>&#x1f4a7; Monitoring Wells \u00b7 Aquifer Sampling \u00b7 Glyphosate \u00b7 Potability \u00b7 HPLC-MS\/MS \u00b7 Table 2 Decree 831\/93 Underground Water Groundwater monitoring well construction, aquifer surveillance, drinking water potability and contaminated site groundwater characterisation. Biogroup provides a complete groundwater service \u2014 from the design and construction of monitoring wells (phreatimeters) and hydraulic levelling to representative low-flow&#8230;<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"_joinchat":[],"footnotes":""},"class_list":["post-989689","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Underground Water - BioGroup<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/biogroup.com.ar\/en\/underground-water\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Underground Water - BioGroup\" \/>\n<meta property=\"og:description\" content=\"&#x1f4a7; Monitoring Wells \u00b7 Aquifer Sampling \u00b7 Glyphosate \u00b7 Potability \u00b7 HPLC-MS\/MS \u00b7 Table 2 Decree 831\/93 Underground Water Groundwater monitoring well construction, aquifer surveillance, drinking water potability and contaminated site groundwater characterisation. Biogroup provides a complete groundwater service \u2014 from the design and construction of monitoring wells (phreatimeters) and hydraulic levelling to representative low-flow...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/biogroup.com.ar\/en\/underground-water\/\" \/>\n<meta property=\"og:site_name\" content=\"BioGroup\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-19T18:47:27+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"16 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/biogroup.com.ar\\\/en\\\/underground-water\\\/\",\"url\":\"https:\\\/\\\/biogroup.com.ar\\\/en\\\/underground-water\\\/\",\"name\":\"Underground Water - BioGroup\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/biogroup.com.ar\\\/#website\"},\"datePublished\":\"2022-11-16T18:36:19+00:00\",\"dateModified\":\"2026-05-19T18:47:27+00:00\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/biogroup.com.ar\\\/en\\\/underground-water\\\/\"]}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/biogroup.com.ar\\\/#website\",\"url\":\"https:\\\/\\\/biogroup.com.ar\\\/\",\"name\":\"BioGroup\",\"description\":\"Centro de Investigaci\u00f3n Cient\u00edfica y Tecnol\u00f3gica\",\"publisher\":{\"@id\":\"https:\\\/\\\/biogroup.com.ar\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/biogroup.com.ar\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/biogroup.com.ar\\\/#organization\",\"name\":\"BioGroup\",\"url\":\"https:\\\/\\\/biogroup.com.ar\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/biogroup.com.ar\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/biogroup.com.ar\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/cropped-logo-1.jpg\",\"contentUrl\":\"https:\\\/\\\/biogroup.com.ar\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/cropped-logo-1.jpg\",\"width\":573,\"height\":145,\"caption\":\"BioGroup\"},\"image\":{\"@id\":\"https:\\\/\\\/biogroup.com.ar\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Underground Water - BioGroup","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/biogroup.com.ar\/en\/underground-water\/","og_locale":"en_US","og_type":"article","og_title":"Underground Water - BioGroup","og_description":"&#x1f4a7; Monitoring Wells \u00b7 Aquifer Sampling \u00b7 Glyphosate \u00b7 Potability \u00b7 HPLC-MS\/MS \u00b7 Table 2 Decree 831\/93 Underground Water Groundwater monitoring well construction, aquifer surveillance, drinking water potability and contaminated site groundwater characterisation. Biogroup provides a complete groundwater service \u2014 from the design and construction of monitoring wells (phreatimeters) and hydraulic levelling to representative low-flow...","og_url":"https:\/\/biogroup.com.ar\/en\/underground-water\/","og_site_name":"BioGroup","article_modified_time":"2026-05-19T18:47:27+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"16 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/biogroup.com.ar\/en\/underground-water\/","url":"https:\/\/biogroup.com.ar\/en\/underground-water\/","name":"Underground Water - BioGroup","isPartOf":{"@id":"https:\/\/biogroup.com.ar\/#website"},"datePublished":"2022-11-16T18:36:19+00:00","dateModified":"2026-05-19T18:47:27+00:00","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/biogroup.com.ar\/en\/underground-water\/"]}]},{"@type":"WebSite","@id":"https:\/\/biogroup.com.ar\/#website","url":"https:\/\/biogroup.com.ar\/","name":"BioGroup","description":"Centro de Investigaci\u00f3n Cient\u00edfica y Tecnol\u00f3gica","publisher":{"@id":"https:\/\/biogroup.com.ar\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/biogroup.com.ar\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/biogroup.com.ar\/#organization","name":"BioGroup","url":"https:\/\/biogroup.com.ar\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/biogroup.com.ar\/#\/schema\/logo\/image\/","url":"https:\/\/biogroup.com.ar\/wp-content\/uploads\/2024\/10\/cropped-logo-1.jpg","contentUrl":"https:\/\/biogroup.com.ar\/wp-content\/uploads\/2024\/10\/cropped-logo-1.jpg","width":573,"height":145,"caption":"BioGroup"},"image":{"@id":"https:\/\/biogroup.com.ar\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/biogroup.com.ar\/en\/wp-json\/wp\/v2\/pages\/989689","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/biogroup.com.ar\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/biogroup.com.ar\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/biogroup.com.ar\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/biogroup.com.ar\/en\/wp-json\/wp\/v2\/comments?post=989689"}],"version-history":[{"count":5,"href":"https:\/\/biogroup.com.ar\/en\/wp-json\/wp\/v2\/pages\/989689\/revisions"}],"predecessor-version":[{"id":993311,"href":"https:\/\/biogroup.com.ar\/en\/wp-json\/wp\/v2\/pages\/989689\/revisions\/993311"}],"wp:attachment":[{"href":"https:\/\/biogroup.com.ar\/en\/wp-json\/wp\/v2\/media?parent=989689"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}